Complete Flue Solutions Ltd (CFS) specialises in the supply and installation of industrial, commercial and domestic flue and exhaust systems.
As a trade customer or a commercial specifier, you can purchase flue systems and any ancillary components directly and competitively from us. We offer our fast supply and delivery service throughout the UK.
CFS will also provide a full design specification and installation service where required, with full technical backup from our team of qualified engineers.
To find the product(s) which you require, first select the fuel type for your installation:
| Appliance with draught diverter and flue gas temperature below 250° |
|
|
|
|
A |
|
|
|
|
|
| Gas fire to BS 7977-1:2000 |
|
|
|
|
|
|
|
|
|
|
| ILFE Gas Fire to BS 7977-1:2000 |
|
|
|
|
|
|
|
|
|
|
| Decorative gas fire to BS EN 509:2000 |
|
B |
B |
|
|
|
B |
|
|
B |
| Other decorative gas fires |
|
F |
F |
|
|
|
F |
|
|
F |
| Fan Powered non-condensing |
|
|
|
|
|
|
|
|
|
|
| Fan Powered condensing |
|
|
|
|
E |
|
E |
|
|
|
| Radiant/Unit/Cabinet Heaters |
|
|
|
|
|
|
|
|
|
|
Specialist Application Diesel generator exhausts, smoke duct, kitchen extract and dry partical movement |
|
|
|
|
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Appliance with draught diverter and flue gas temperature below 250°C |
|
|
|
|
|
|
|
D |
|
|
| Appliance with flue gas temperature above 250&dec;C |
|
F |
F |
|
|
|
F |
|
|
F |
| Pressure jet appliance 28sec/35sec, oil non-condensing |
|
|
|
|
|
|
|
D |
|
|
| Plant/equipment burning 200-3500 sec. oil |
|
|
|
|
|
|
|
|
|
|
| Pressure jet appliance condensing |
|
|
|
|
E |
|
E |
|
|
|
| Radiant/Unit/Cabinet/Heaters |
|
|
|
|
|
|
|
|
|
|
Specialist Application Diesel generator exhausts, smoke duct, kitchen extract and dry partical movement |
 |
|
|
|
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Boiler or closed room heater/stove |
|
F |
F |
|
|
|
F |
|
|
F |
| Open fire without boiler |
|
F |
F |
|
|
|
F |
|
|
F |
| Open fire with back boiler |
|
F |
F |
|
|
|
F |
|
|
F |
Specialist Application Diesel generator exhausts, smoke duct, kitchen extract and dry partical movement |
 |
|
|
|
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Boiler or closed room heater/stove without boiler |
|
F |
F |
|
C |
|
F |
|
|
F |
| Boiler or closed room heater/stove with boiler |
|
F |
F |
|
C |
|
F |
|
|
F |
| Open fire without boiler |
|
F |
F |
|
C |
|
F |
|
|
F |
| Open fire with back boiler |
|
F |
F |
|
C |
|
F |
|
|
F |
Specialist Application Diesel generator exhausts, smoke duct, kitchen extract and dry partical movement |
 |
|
|
|
|
|
|
|
|
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
A - Flue pipe connection from appliance to chimney
B - Unless approval relaxed for use with 125mm gas vents
C - Flue pipe connection from appliance to chimney, 1mm min. thickness, or as chimney liner
D - Non-condensing appliances, 28 sec, oil, max 250°C FGT
E - Where using optional seals, max 200°C FGT
F - When using Ventilated Support Components on internally applied systems